SUPERIORTM GSA Chlorinator Series CLM-2/5
200 PPD & 500 PPD - 5kg/hr & 10kg/hr
For Cylinder Wall Manifold or Ton Container Mounting
|
|
| |
| |
GENERAL
DESCRIPTION
The SUPERIORTM Series CLM-2/5 Gas Chlorinator
is a state-of-the-art, vacuum-operated, solution feed
type which mounts directly on a chlorine valve. The chlorinator
is mounted onto the chlorine valve of a cylinder, wall
manifold or ton container adaptor, using a very heavy-duty,positive
yoke clamp connection. A chlorine gas flow meter indicates
the amount of chlorine being fed. Chlorine flow rate is |
| manually adjusted and the deaign
permits easy addition of a number of automatic flow rate
control devices. A high efficiency, water operated ejector
produces the vacuum necessary to operate the system. The
ejector assembly contains a back-flow check valve system
to prevent pressurized water from entering the chlorinator.
A sprong-opposed diaphragm vacuum regulator controls the
chlorine gas flow rate and also acts as the safety shut-off
valve. |
|
|
|
FEATURES |
THE SUPERIORTM Series CLM-2/5 presents
the most modern design technology coupled with the very best
materials avilable to create an outstanding, user friendly piece
of equipment. It is designed with user safety as a primary concern.
1. A new ultra-thick, fluoroplastic yoke coating
gives SUPERIORTM corrosion resistance, won’t diffuse through
it to cause coating bubbling and peeling.
2. All molded parts are fiber-glass reinforced
ABS plastic, designed for SUPERIORTM strength, warp-resistance
and chlorine resistance.
3. The rate valve “seat” is pure fluoroplastic
and will not swell, stick or become brittle with age or exposure
to liquid chlorine.
4. All external bolts and nuts are Titanium
for complete corrosion resistance..a SUPERIORTM exclusive There
are no stainless steel or monel nuts and bolts to corrode and
freeze up in the presence of moist chlorine gas.
5. Extra heavy-duty outlet threads on the
ejector diffuser prevents breakage from over-tightening or “bumping”
of the ejector assembly.
6. The “Universal” ejector diffuser allows
use of high pressure solution hose, direct ejector monting in
mains, or in-line piping with rigid solution pipe, without special
adaptors.
7. Easier to service and perform routine maintenance,
with standard size wrench lugs provided on all screwed-together
ejector parts. No more pipe wrenches to accidentally tear and
scrape plastic surfaces.
8. All vacuum fitting hloes are heavily renforced
to prevent the possibility of cracking from over-tightening
fittings.
9. “dual-pressure” check valve is standard
on all SUPERIORTM gas Chlorinators. Proven high back-pressure
unitized check valve design protects against sudden surges up
to 300 PSIG while a spring-loaded diaphragm check provides positive
shut off even when there is no back-pressure to force the seat
closed.
10. Fewer parts, combined with SUPERIOR materials
and SUPERIOR design gives you a SUPERIORTM Gas Chlorinator. |
| FLOW
METER CAPACITIES |
| A dual English/Metric scale variable area flow
metering tube is provided with a maximum capacity of 200 pounds
per 24 hours-5kg/hr (Model CLM-2) or 500 pounds per 24 hours-10kg/hr
(Model CLM-5). All metering tubes are interchangeable and may
be changed in the field without special tools. |
| MODULAR
DESIGN |
| SUPERIORTM Gas Chlorinators have been
designed to give the maximum flexibility in system installation.
The vacuum regulator and metering tube panel are close coupled
and mounted onto the chlorine cylinder as a single assembly.
The ejector can be located wherever plumbing and/or hydraulic
conditions make it most desirable. Modular design also makes
it easy and inexpensive to expand or upgrade the system. The
metering tube panel may be detached from the vacuum regulator
at any time, in just a few minutes, if future requirements or
safety dictate a remote metering application, or multiple point
chlorination is desired. |
| MATERIALS OF CONSTRUCTION |
| One of SUPERIOR’S major competitive
advantages is the use of the finest, strongest and most durable
materials available. Extensive use of Fluoroplastics and fiberglass
reinforced thermoplastics allow SUPERIORTM Gas Chlorinators
to withstand attack by chlorine in any form and to give the
longest operational lift. Many parts are guaranteed for the
lift of the equipment against chlorine damage. |
| SYSTEM OPERATION |
The vacuum regulator is securely clamped
onto the chlorine valve. Water under pressure flows through
the ejector at high velocity which causes a strong vacuum to
be created. This opens the check valves in the ejector assembly
and transmits a vacuum signal through the meter tube/rat valve
panel back to the vacuum regulator. When the vacuum reaches
a pre-set level, the diaphragm in the regulator moves to open
the chlorine inlet safety valve, permitting gas to flow from
the chlorine cylinder. The spring-opposed diaphragm and inlet
valve regulate the vacuum at this point.
Chlorine gas passes through the flow meter panel and rate control
valve to the ejector. The gas mixes with the ejector water and
is discharged through the diffuser into the water being treated. |
|
|
| SPECIFICATIONS |
The chlorinator shall be SUPERIORTM
MODEL CLM-2/5 manufactured by Chemical Injection Technologies,
Inc.,FT. Pierce, Florida, and shall have a maximum capacity
of pounds per day (gr/hr) of chlorine feed and shall be equipped
with a chlorine flow meter of pounds per day (gr/hr).
The chlorinator shall consist of a close-coupled vacuum regulator/flow
meter, and ejector/check valve. Each of these assemblies shall
be capable of being individually located wherever safety and/or
operator convenience dictated. The vacuum regulator/flow meter
assembly shall be capable of being separated into independent
vacuum regulator and metering panel assemblies at any time for
remote metering or multiple point chlorination applications.
The vacuum regulator/flow meter shall mount directly on the
chlorine valve of a chlorine cylinder, wall manifold or ton
container adaptor by means of a positive yoke type clamp having
an integral tightening screw with slide bar handle. No wrenches
of other tools shall be required to mount or dismount the vacuum
regulator from the chlorine valve. The chlorine valve/chlorinator
inlet which shall be inert to the effects of wet . dry or liquid
chlorine. The and shall be capable of removing impurities greater
than 25 microns. A pressure relief valve shall be incorporated
into the vacuum regulator to prevent pressure from building
up in the system. All external screws and nuts shall be mand
of Titanium to prevent corrosion.
The vacuum regulator/flow meter bodies shall be constructed
of fiberglass reinforced thermoplastic material and shall incorporate
a flow rate control valve made of fluoroplastic material which
is inert to the corrosive effects of chlorine. The rate valve
metering tip shall be constructed of pure silver. Design shall
provide for full closing of the rate valve without engaging
the control surfaces, to prevent damage.
Vacuum shall be created by a fixed-throat venture/ejector system
connected directly to the chlorine solution diffuser. A dual
high-pressure/low-pressure check valve system shall prevent
water from entering the gas system. The ejector assembly shall
be capable of withstanding water pressure up to 300 PSIG(20.7
Bars). A universal-type chlorine solution diffuser shall be
provided which shall allow close-coupling of the ejector to
a water main, use of flexible solution hose or rigid solution
pipe without the use of special adaptors. |
| STANDARD ACCESSORIES |
50ft.-Vent & vacuum tubing
10-Lead cylinder connection gaskets
1-Vent insect screen |
| OPTIONAL ACCESSORIES
AVAILABLE |
Inlet Water Assembly Gas Masks
Wall manifold kits Gas Detectors
Booster pumps Scales
Residual Analyzers Gauges
Automatic Controls Chlorine Comparators
Ton Container Adaptors Others Available
|
| OTHER SUPERIORTM
SYSTEMS AVAILABLE |
AUTOMATIC SWITCHOVER GAS CHLORINATORS
MULTIPLE-POINT GAS CHLORINATORS
100POUNDS PER DAY(2000 GR/HR)
500 POUNDS PER DAY (10 KG/HR)
GAS SULFONATORS (DECHLORINATOR)
AMMONIATORS
AUTOMATIC FLOW PROPORTIONING
AUTOMATIC RESIDUAL CONTROL |
|