SUPERIORTM Chlorine Residual Analyzer Model SA-100
Continuous Flow Measuring Cell Analyzer
|
|
| |
| |
GENERAL
DESCRIPTION
The SUPERIORTM Model SA-100 Chlorine Residual
Analyzer uses a continuous flow measuring cell with a
built in flow regulator. The SA-100 is nearly maintenance
free, using electrodes which are constantly cleaned by
the continuous flow of water over the electrodes. The
configuration of the SA-100 Chlorine Residual Analyzer
requires cleaning and calibration only once every two
to six months, depending on water quality. The SUPERIORTM
SA-100-CLT, for use with free chlorine, Yearly replacement
of the main |
| measuring probe
at a low cost is recommended, leaving the SA-100-CLF easy
and inexpensive to maintain. The SUPERIORTM SA-100-CLF
Total Chlorine Residual Analyzer is also nearly maintenance
free, requiring simple replenishment of the electrolyte
solution every 1 1/2 to 2 months, depending on water quality,
and yearly replacement of the membrane cap from the total
chlorine electrode. |
|
|
|
FEATURES |
THE SUPERIORTM Series SA-100 represents
the most modern design technology coupled with the best materials
available to create an outstanding, user friendly piece of equipment.
It is designed with user safety as a primary concern.
● Continuous flow measuring cell
● Built flow regulator: 15-120 psl
● Wide supply voltage: 85-260 VAC, 50-60 hz
● Loop power:4-20 MA
● 400 ohm maximum load.
● Measuring ranges:0-0.200, up to 0-200.00 ppm(mg/L). Standard
ranges are: 0-3/5/10 ppm(mg/L), with other ranges available.
(Measuring ranges depend on the analyzed substances.)
● Resolution:0.01 ppm(mg/L)
● Accuracy: BETTER than 1%
● Sample flow:57 L/hr
● Protection: NEMA 4
|
| APPLICATION |
The SUPERIORTM Model SA-100 is designed for use
in:
● Wastewater treatment
● Water purification
● Chlorination
● Dechlorination
● Swimming pools
● Cooling towers-air scrubbers
● Food and beverage processing
SUPERIORTM design provides ease of operation with top performance.
The SUPERIORTM Chlorine Residual Analyzer can be placed where
most convenient for the operator for ease of use and of maintenance,
and the SA-100 is nearly maintenance free.
Materials used in manufacturing the SUPERIORTM Model SA-100
have been carefully selected for their superior quality and
performance in situations and conditions far more extreme than
conditions to be encountered in actual use. |
| OPERATION |
The SUPERIORTM Chlorine Residual Analyzer
sends out a 4-20 millliamp signal, which can be utilized by
an automatic chemical feed controller, a chart recorder, or
other indicating devices or telemetry equipment, such as SCADA..
A gold electrode is supplied with constant voltage generated
by a precision voltage generator. A preamplifier and a power
amplifier are used for feedback to stabilize the analyzer’s
measuring voltage. Therefore, the system is independent of the
conductivity of the water. The signal will be constant if the
measurement is done in 100 us-water or in brine solution. The
substance specific measuring voltage differs depending on which
substance is to be analyzed. With the substance specific measuring
voltage supplied between the nickel and the gold electrode –
a current differs and depends on the concentration of the substance
to be analyzed. The flow of current is linear to the concentration
guaranteeing high accuracy of the analyzer. |
| SPECIFICATIONS |
The chlorine analyzer shall be SUPERIORTM
Model SA-100 ,manufactured by Chemical injection Technologies,
in., fort pierce, Florida, and shall have a measuring range
of 0- parts per million. The SUPERIOR Model SA-100 shall come
precalibrated, as a complete package, including all necessary
items for quick, efficient start up. The package shall include
a switching power supply of 85 to 240 VAC in and 24VDC out,
with a replaceable electrode.
Sampling system requirements: Sample pump or line pressure must
allow for constant flow rate between 15 and 30 liters per hour(4-8
gallons per hour). A steady flow must be maintained through
the measuring sell. Solids and debris must be filtered out.
Pressurized system requirements: The system is to allow between
15adn 120 psi. The flow regulator is to maintain a steady flow
through the measuring chamber. The sampling water within the
system is not to be lost; the system shall allow for sampling
water to be fed back to a bank. Solids and debris must be filtered
out. |
|
|
| STANDARD PACKAGE |
Switching power supply:85to 240 VAC
out
Replaceable Electrode Membrane cap
Wall Mounting Panel with Flow Regulator /Measuring Cell / LED
Display |
| OTHER SUPERIORTM
SYSTEMS AVAILABLE |
(For Vacuum Operation)
AUTOMATIC SWITCHOVER GAS CHLORINATORS
MULTIPLE-POINT GAS CHLORINATORS
GAS SULFONATORS (DECHLORINATOR)
AMMONIATORS
AUTOMATIC FLOW PROPORTIONING
AUTOMATIC RESIDUAL CONTROL
ELECTRONIC GAS FEED RATE CONTROL VALVES |
|